![]() ![]() You’ll see the difference when you look through a Nikon Total Station even in the low-visibility conditions typical in the field. Nikon’s legendary optics effectively allow in more light to give you brighter, clearer images. The NPL-322+ Total Stations deliver an economic, versatile, and easy-to-use platform to ensure you get the job done right. L.Convenient and long-lasting Li-ion battery Ensure that settings match on both the instrument and MicroSurvey program before every test. ![]() Repeat steps 8a to 8j (excluding 8d) but use the comm settings recorded in step 8d rather than the FG or EVR default settings. K.If this fails, return to the instrument control panel and change the settings back to those you recorded in step 8d. set communication parameters to match those that were set on the instrument note if communication parameters differ from those set on the instrument before you change anything. *ensure EXT COMM is set to "NIKON" and that you are using a Nikon cable before proceeding*ĭ. J.If this fails, proceed to step 8 (BUT still use a non-Nikon cable) Ensure that settings match on both the instrument and FG or EVR program before every test. Repeat steps 7a to 7h (excluding 7d) but use the comm settings recorded in step 7d rather than the FG or EVR default settings. I.If this fails, return to the instrument control panel and change the settings back to those you recorded in step c. set communication parameters in EVR or FG to match those that were set on the instrument note if communication parameters in FG or EVR differ from those set on the instrument before you change anything. *ensure EXT COMM is set to "SET" and that you are using a non-Nikon cable before proceeding*ĭ. If EXT COMM you noted in step 3 was "NIKON," select the NIKON make and start at step 8 ![]() If EXT COMM you noted in step 3 was "SET," select the Sokkia make and start at step 7 Pick "Edit" and proceed to "Model and Communication" Open FG or EVR and create a new instrument profile. tumble the scope vertically 360 degrees and ensure the instrument is levelĦ. back out of all menus on the instrument so it is displaying HA,VA, SD etcĥ. any other communication settings will probably be the same as the defaults in FG or EVR (ie: parity none, 8 data bits, 1 stop bit) we won't change them unless we have toĤ. find the Communication Parameters (COMM settings) and take note of the baud rate. It will be set to either Nikon or SET, take note of that ![]() Open up the instrument control panel on the total station and check: By default this is 1 but you must consult the data collector documentation or contact the data collector support team to be sure.ģ. determine which Port number your data collector uses to connect by cable. Ensure that your cable is Nikon for Nikon, non-Nikon for SokkiaĢ. Total station nikon serial#*Note that this guide will help when you are using a Serial cable, NOT Bluetooth, a USB cable or a serial USB adapter*ġ. We makes notes when we have success in our "Supported Hardware" resource you can link to here.īut if you can't find notes about your specific instrument, here are the steps to follow: Over the years we have noted which communication parameters allow customers to connect with their Nikon or Sokkia Instruments in FieldGenius or Evidence Recorder when they are using a serial cable. Posted by James Johnston on 30 August 2022 07:33 AM ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |